Perfformiad technegol
| Prawf foltedd gwrthsefyll AC | 117kV, 5 munud |
| Prawf rhyddhau rhannol ar dymheredd ystafell | 45kV |
| Prawf foltedd byrbwyll | 95℃~100℃, 200kV |
| Prawf rhyddhau rhannol tymheredd uchel | 95℃~100℃, 45kV |
| Prawf cylch llwyth pwysau cyson mewn aer | 65kV |
| Prawf sefydlogrwydd deinamig cylched fer | 85.0kA |
20kVcrebachu oer craidd senglategolion ceblenw cynnyrch a model manyleb
| Math o atodiad | Manyleb y cebl (mm²) | Manyleb a model | |
|
Cebl craidd sengl | Terfynell dan do un craidd | 50-120 | NSY-35/1.1 |
| 150-240 | NSY-35/1.2 | ||
| 300-400 | NSY-35/1.3 | ||
| 500-630 | NSY-35/1.4 | ||
| Terfynell awyr agored un craidd | 50-120 | WSY-35/1.1 | |
| 150-240 | WSY-35/1.2 | ||
| 300-400 | WSY-35/1.3 | ||
| 500-630 | WSY-35/1.4 | ||
| Cysylltydd canolradd craidd sengl | 50-120 | JSY-35/1.1 | |
| 150-240 | JSY-35/1.2 | ||
| 300-400 | JSY-35/1.3 | ||
| 500-630 | JSY-35/1.4 | ||
|
Cebl tair craidd | Terfynell dan do tair craidd | 50-120 | NSY-35/3.1 |
| 150-240 | NSY-35/3.2 | ||
| 300-400 | NSY-35/3.3 | ||
| 500-630 | NSY-35/3.4 | ||
| Terfynell awyr agored tair craidd | 50-120 | WSY-35/3.1 | |
| 150-240 | WSY-35/3.2 | ||
| 300-400 | WSY-35/3.3 | ||
| 500-630 | WSY-35/3.4 | ||
| Cysylltydd canol tair craidd | 50-120 | JSY-35/3.1 | |
| 150-240 | JSY-35/3.2 | ||
| 300-400 | JSY-35/3.3 | ||
| 500-630 | JSY-35/3.4 |